Anechoic Chambers for Antenna, Radar and Wireless Testing

An anechoic chamber is not a room with foam on the walls. It is a quiet zone of a stated size, at a stated distance, inside a shielding enclosure whose penetrations are accounted for. If a quote does not name the quiet zone, it has not told you what you are buying.

What we supply

Microwave anechoic chambers for antenna pattern and gain measurement, RCS work, radar and microwave component testing, and wireless device certification. Absorber on all six faces, or five faces plus a reflective floor where a ground plane is required for EMC work.

The HM-MC antenna chamber, in numbers

ItemValue
Typical outer dimensions7.0 × 4.0 × 3.0 m (L × W × H), other sizes on request
Shield module3 m × 1 m, double-sided hot-dip galvanised steel ≥ 2 mm, zinc layer ≥ 20 μm
Module jointconductive gasket between adjacent modules, M10 bolted
AbsorberHM-AM pyramidal PU or EPP, sized to the lowest frequency of interest
Shielded door1.0 × 2.0 / 1.2 × 2.0 / 1.5 × 2.0 m — manual, electric or pneumatic
Turntableø1.2 m or ø1.5 m, 300 kg or 500 kg load
Antenna mast0.9 m to 2.0 m working height
Raised floor300 mm
Shielding performancemeets and typically exceeds EN 50147-1

The construction order from inside out is: absorber, anti-corrosion plywood backing, shielding module. The plywood is not decoration — it spreads the load of the absorber and stops the pyramid bases from wearing against the steel modules when the room is re-lined years later.

Quiet zone is a function of absorber length, not room size

This is where most small-chamber projects go wrong. A 200 mm pyramid stops absorbing usefully around 300 MHz at normal incidence, so a room lined only with 200 mm pyramid has no quiet zone below that. To reach 30 MHz you need either very long pyramids (which eat metres of interior volume) or hybrid ferrite tiles under the pyramid.

AbsorberHeightUseful fromTypical use
AM-3030 mm≈ 3 GHzhigh-frequency only, small test boxes
AM-100100 mm≈ 1 GHzcompact antenna chambers
AM-200200 mm≈ 300 MHzgeneral microwave work
AM-500500 mm≈ 100 MHzwide-band antenna and RCS
Ferrite 6.7 mm + pyramidhybrid≈ 30 MHzfull EMC band without huge pyramids

Rule of thumb we use in quoting: interior size must be at least the quiet zone plus two absorber lengths plus one wavelength of clearance. Anything less and the quiet zone is theoretical.

Ferrite tile specification

ItemValue
Tile size99.95 × 99.95 mm
Thickness6.7 mm or 5.5 mm
Weight0.33 kg (6.7) / 0.28 kg (5.5)
Operating range30 MHz to 1 GHz, extended to 18 GHz by hybrid pyramid
Max service temperature85 °C
Firenon-flammable, sintered ferrite base
Mountingscrewed to structure or glued to shielding enclosure
Manufacturingall six faces ground flat, to minimise tile-to-tile gaps

The gap between tiles matters more than the tile itself. Unground tiles stacked by hand leave 1–2 mm gaps, and at 300 MHz that is the difference between a working chamber and one that fails. Ask whether the tiles are surface-ground on all six faces.

Acceptance tests

What we tell customers who ask for a 3 m chamber with a 30 MHz quiet zone. It cannot be done in 3 m of interior space. Either the room grows, or the test band starts at 200–300 MHz, or you accept a smaller quiet zone. We will say this before quoting rather than after the deposit. Chambers sold into a building that was already designed around the wrong size are the most expensive mistake in this business.

Frequently asked

Can the chamber be assembled inside an existing room?

Yes — modular panels are 3 m × 1 m and pass through a standard 1.2 m door. A 7 × 4 × 3 m chamber has been installed in a basement using only a passenger lift and a hand truck.

Who carries out the acceptance test?

An independent accredited laboratory. We do not accept our own chamber with our own instrument; for CNAS, DILAC or military laboratory certification, the third-party report is what the auditor wants.

Can you upgrade an existing chamber?

Usually yes — re-lining absorber, replacing doors and seals, adding filters and vents. Performance of the shell rarely degrades; the doors, gaskets and penetrations usually do.