A shielded room is only as good as its worst penetration. Every cable that enters the room carries interference in and out. HMEMC builds the filters that close that hole: single and three phase mains filters from 3 A to 2200 A, 400 Hz and DC variants, and signal, telephone, USB, LAN and fire alarm filters for everything else that has to get inside.
Panels are the easy part of a shielded room. A well-built enclosure with a badly chosen filter leaks along the power cable, and the measurement fails at the frequencies nobody tested during installation. In practice most shielding performance complaints trace back to a penetration, not to the panel seams.
Two things make a mains filter work in this application: enough insertion loss across the band you actually care about, and correct installation — short, shielded cable runs on the clean side, and the filter housing bonded to the room's shielding. A filter bought on current rating alone is a filter bought twice.
Standard ranges, all with manganese-zinc ferrite cores and multi-stage LC construction:
| Current | Configurations |
|---|---|
| 3 A – 6 A | 2-wire and 4-wire, C grade, 220 V / 380 V |
| 10 A – 20 A | 2 x 10 A, 4 x 10 A, 2 x 16 A, DC variants, 400 Hz variants |
| 30 A | 2 x 30 A and 4 x 30 A, single and three phase, military EMP variants |
| 50 A – 80 A | 2 x 50 A, 4 x 50 A, 2 x 60 A, 4 x 80 A at 115 V, 250 V and 400 Hz |
| 100 A – 150 A | 1 x 100 A, 2 x 100 A, 4 x 100 A, DC up to 1000 V, 400 Hz, 440 V |
| 200 A – 300 A | 1 x 200 A, 2 x 200 A, 4 x 200 A, 4 x 250 A, 4 x 300 A at 400 Hz |
| 400 A – 2200 A | 4 x 400 A, 4 x 500 A, 4 x 600 A, 2 x 800 A, 2 x 2200 A |
Typical insertion loss on standard designs is 100 dB from around 100 kHz to 40 GHz in the common mode, with the differential mode curve specified separately per model — a filter cannot be judged by one number, and any supplier quoting a single figure is hiding the shape of the curve.
The mains feed is only one penetration. A typical chamber has a dozen more:
Every one of these exists because somebody tried to run the cable straight through and watched the shielding effectiveness collapse. If your room needs a signal type that is not on this list, that is a design conversation, not a catalogue problem.
On the actual load current plus margin, but the rating is only the starting point. What matters is the insertion loss curve over the frequency range your test standard covers, and the mounting arrangement.
Yes. Filters are supplied as standalone components, including to customers who are building or upgrading rooms themselves.
We build 400 Hz, DC, 440 V and EMP variants as standard ranges. Anything further out is a custom design — send the specification.
Telephone, USB, LAN, RS485, video, DVI, audio, fire alarm and fibre optic feedthroughs are all available. Fibre is usually the better answer for any signal that can be converted.
Five fields, no registration. We reply to every enquiry within one working day.