Mobile Shielded Rooms: Built to Travel, Not Just to Shield
A mobile shielded room is an argument with physics. You want a room that goes on a truck, survives the road, bolts together in a day, and still attenuates 80 dB. Those four things pull against each other, and where a supplier compromises decides whether the room is a field shelter or a laboratory that happens to be movable.
What "mobile" covers, and they are not the same problem
| Type | What moves | Typical use | Where it gets hard |
|---|---|---|---|
| Relocatable panel room | Panels come apart, transport flat, re-erect elsewhere | Rented floors, temporary test sites, a lab that will move in two years | Panel and gasket survival across moves, re-alignment at the joints |
| Shielded shelter on a vehicle | The whole shelter travels on a chassis | Military, field EMC, mobile command | Vibration, thermal cycling, weather sealing, weight |
| Mobile shielded cabinet | A bench or trolley sized enclosure | R&D screening, production test, a device that needs isolating where it sits | Door seals at small sizes, connector density |
We build all three, and we will say which one your requirement actually needs once we know whether you are moving once or moving weekly.
A shielded shelter door, specified to a military standard
The numbers below come from a technical agreement we signed in November 2025 with Shanxi Zhongdian Technology Special Equipment for an 80 dB shielded shelter door, model KY007. It is the clearest example of what a field shelter door has to survive compared to a laboratory door.
Structure
Door frame, leaf and locking mechanism. The frame carries an external mounting flange with a drainage channel and a rubber weather seal, with the shielding spring strip in the middle. The leaf is 50 mm thick: a steel skin, embedded plates for hinges and limits, and the remaining cavity filled and bonded with polyurethane as one solid piece, so the leaf cannot drum or delaminate. Locking is a vertical synchronised linkage inside the leaf.
Shielding, and it is honest about the low end
| Frequency | Attenuation |
|---|---|
| 14 kHz | ≥ 55 dB |
| 150 kHz | ≥ 65 dB |
| 15 MHz, 100 MHz, 450 MHz, 950 MHz, 3 GHz, 6 GHz, 10 GHz, 18 GHz | ≥ 80 dB at each |
A laboratory door would be quoted at 100 dB from 1 MHz up. This one is 80 dB, and 55 dB at 14 kHz. That is not a lesser product, it is a door whose leaf is 50 mm of steel-faced polyurethane on a moving shelter, and the low frequency magnetic figure follows from that wall thickness. Anyone quoting 100 dB at 14 kHz for a shelter door is either quoting a different structure or has not tested it.
The seal, which is the whole door
Double knife, three spring strips. Three layers of beryllium copper finger strip on the outer frame, meshing with the knife edge on the leaf. The strip is formed as an arc so contact with the knife face is a line, not a patch. That matters in the field more than in a lab: an arc-shaped strip wipes dust off the contact surface as the door closes, instead of pressing it in.
Spring strips are single pieces 450 mm long, clamped by a retaining bar. A damaged strip is replaced by backing out the bolts around it, without removing the bar, and on the frame side the aluminium extrusion is segmented so one segment comes off on its own. Field repairability was a requirement here, not a feature.
Life: the spring strips passed a 30 000 cycle open-close fatigue test with no deformation or breakage.
The handle shaft, where a door quietly leaks
The handle shaft has to pass through the leaf thickness and it has to turn, so there is a gap, so it behaves like an antenna through the shield. The fix is a groove machined into the shaft at mid thickness with a circular spring ring in it, so the shaft stays in contact with the bush as it turns. Piston ring, essentially. This is the kind of detail that separates a door that tests at 80 dB from one that tests at 60 dB and blames the customer's test setup.
Mechanics
| Parameter | Value |
|---|---|
| Clear opening | 1 600 mm high × 700 mm wide |
| Aperture cut in the shelter panel | 1 760 × 940 mm |
| Overall door size | 1 840 × 1 020 mm |
| Leaf thickness | 50 mm |
| Outer flange return | 40 mm, 1.5 mm thick |
| Handle torque at the tail | under 40 N·m |
| Locking | two point synchronised, handle to gear and rack to roller and wedge, 70 mm total travel made up of 60 mm wedge travel, 5 mm start and a 5 mm flat at the end |
| Surface flatness | better than 3/1 000 |
| Hinge opening angle | 110°, with a limit stop |
| Lockout | padlockable from outside, still opens from inside when locked |
That last line is an escape requirement and it is not optional on a manned shelter.
Materials, chosen for different reasons
Outer skin is stainless iron, because it only sees weather and carries no shielding duty. The knife is carbon steel, chosen for wear resistance at the contact line even though it is magnetic. The spring strip is beryllium copper with electroless nickel plating for corrosion. Three materials on one door because three different jobs.
Environmental, to GJB 6109-2007
| Condition | Requirement |
|---|---|
| Operating temperature | −45 °C to +55 °C |
| Storage temperature | −55 °C to +70 °C |
| Thermal shock | +70 °C to −55 °C cycling |
| Mould | GJB 150.10A, growth grade 0 to 2 |
| Salt spray | GJB 2093A, no coating or plating detachment |
| Damp heat | 95 % RH at 30 °C |
| Rain | GJB 6109-2007, 6 mm/min for 1 hour, no leakage |
| Vibration | 60 km motorway plus 20 km ordinary road and dirt, no damage or performance loss |
| Air tightness | 300 Pa overpressure, leakage under 1.0 m³/min |
| Thermal insulation | grade I, overall heat transfer coefficient under 1.5 W/(m²·°C) across a 55 °C differential |
The rain, vibration, salt spray and air tightness requirements are what make this a shelter door rather than a laboratory door. A laboratory door has none of them and does not need them.
Relocatable panel rooms
Where the requirement is a laboratory that may move rather than a shelter that travels, the room is built as bolted modules on the same 3 m × 1 m grid as our fixed rooms, and the design decisions are:
- Panels survive being taken down. The gasket is a replaceable item, and it is specified as such, because a gasket that has been compressed twice will not hold the third time.
- Joints are numbered. Every panel and every joint goes back to the same place. Swapping panels on re-erection is the most common cause of a room that tested at 90 dB in the factory and tests at 70 dB at the new site.
- Penetrations are planned for the move. Filter walls and vent windows are mounted in removable plates, so the shield is not cut a second time at the new site.
- Everything goes flat. Panels, absorber, doors and frames stack and ship as flat as the sizes allow; the door is the only awkward item and it travels as one unit with its frame.
Mobile shielded cabinets
For a single device, a trolley or bench sized shielded enclosure is usually the right answer, and it is a product we hold a utility model patent on: mobile shielded box, patent ZL 2023 2 0227113.X, granted 29 August 2023, publication CN 219612482 U. Inventors Hua Jun, Zhou Ting and Pan Xu.
The patent covers a shielded box on a mobile base with the door and the frame arranged so the seal stays true when the box is moved. That sounds like a small thing and it is the whole problem with mobile cabinets: a box that shields at 90 dB on a bench will walk itself out of alignment once it is on castors and moved a few hundred times.
What you lose by going mobile
Moving a room costs performance, and here is where:
- Low frequency magnetic. Every joint is a gasket, and gaskets age. A welded room holds 14 kHz forever; a movable one holds it until the gaskets are due. Plan on replacing gaskets.
- Door alignment. Fixed rooms set the door once. Movable rooms re-set it every time, and the door is where the loss shows up first.
- Floor treatment. A raised floor and reflecting ground plane can be made to travel, but the joints are less perfect than a poured slab, and it shows in the NSA numbers.
None of these are fatal. All of them should appear in the quotation, and the ones that do not are the ones that will surprise you at the acceptance test.
Frequently asked
How long does re-erection take?
For a panel room in the 3 × 3 × 2.5 m class with a small team and a clear floor, days rather than weeks, plus the shielding test. The test is the part that cannot be compressed.
Does the absorber travel with the room?
Yes, screw mounted so it comes down and goes back up. Ferrite tile does not survive rough handling well, so it ships in the original trays.
Can you ship a shelter as a container?
Panels and doors ship in standard containers, which is how the German project moved: two containers, heaviest pallet 2 100 kg. A complete shelter on a chassis is a different shipment and we will quote it against your route.
Where we have shipped
Market notes and project references, by country:
Ask about mobile shielded rooms