Mobile Shielded Rooms: Built to Travel, Not Just to Shield

A mobile shielded room is an argument with physics. You want a room that goes on a truck, survives the road, bolts together in a day, and still attenuates 80 dB. Those four things pull against each other, and where a supplier compromises decides whether the room is a field shelter or a laboratory that happens to be movable.

What "mobile" covers, and they are not the same problem

TypeWhat movesTypical useWhere it gets hard
Relocatable panel roomPanels come apart, transport flat, re-erect elsewhereRented floors, temporary test sites, a lab that will move in two yearsPanel and gasket survival across moves, re-alignment at the joints
Shielded shelter on a vehicleThe whole shelter travels on a chassisMilitary, field EMC, mobile commandVibration, thermal cycling, weather sealing, weight
Mobile shielded cabinetA bench or trolley sized enclosureR&D screening, production test, a device that needs isolating where it sitsDoor seals at small sizes, connector density

We build all three, and we will say which one your requirement actually needs once we know whether you are moving once or moving weekly.

A shielded shelter door, specified to a military standard

The numbers below come from a technical agreement we signed in November 2025 with Shanxi Zhongdian Technology Special Equipment for an 80 dB shielded shelter door, model KY007. It is the clearest example of what a field shelter door has to survive compared to a laboratory door.

Structure

Door frame, leaf and locking mechanism. The frame carries an external mounting flange with a drainage channel and a rubber weather seal, with the shielding spring strip in the middle. The leaf is 50 mm thick: a steel skin, embedded plates for hinges and limits, and the remaining cavity filled and bonded with polyurethane as one solid piece, so the leaf cannot drum or delaminate. Locking is a vertical synchronised linkage inside the leaf.

Shielding, and it is honest about the low end

FrequencyAttenuation
14 kHz≥ 55 dB
150 kHz≥ 65 dB
15 MHz, 100 MHz, 450 MHz, 950 MHz, 3 GHz, 6 GHz, 10 GHz, 18 GHz≥ 80 dB at each

A laboratory door would be quoted at 100 dB from 1 MHz up. This one is 80 dB, and 55 dB at 14 kHz. That is not a lesser product, it is a door whose leaf is 50 mm of steel-faced polyurethane on a moving shelter, and the low frequency magnetic figure follows from that wall thickness. Anyone quoting 100 dB at 14 kHz for a shelter door is either quoting a different structure or has not tested it.

The seal, which is the whole door

Double knife, three spring strips. Three layers of beryllium copper finger strip on the outer frame, meshing with the knife edge on the leaf. The strip is formed as an arc so contact with the knife face is a line, not a patch. That matters in the field more than in a lab: an arc-shaped strip wipes dust off the contact surface as the door closes, instead of pressing it in.

Spring strips are single pieces 450 mm long, clamped by a retaining bar. A damaged strip is replaced by backing out the bolts around it, without removing the bar, and on the frame side the aluminium extrusion is segmented so one segment comes off on its own. Field repairability was a requirement here, not a feature.

Life: the spring strips passed a 30 000 cycle open-close fatigue test with no deformation or breakage.

The handle shaft, where a door quietly leaks

The handle shaft has to pass through the leaf thickness and it has to turn, so there is a gap, so it behaves like an antenna through the shield. The fix is a groove machined into the shaft at mid thickness with a circular spring ring in it, so the shaft stays in contact with the bush as it turns. Piston ring, essentially. This is the kind of detail that separates a door that tests at 80 dB from one that tests at 60 dB and blames the customer's test setup.

Mechanics

ParameterValue
Clear opening1 600 mm high × 700 mm wide
Aperture cut in the shelter panel1 760 × 940 mm
Overall door size1 840 × 1 020 mm
Leaf thickness50 mm
Outer flange return40 mm, 1.5 mm thick
Handle torque at the tailunder 40 N·m
Lockingtwo point synchronised, handle to gear and rack to roller and wedge, 70 mm total travel made up of 60 mm wedge travel, 5 mm start and a 5 mm flat at the end
Surface flatnessbetter than 3/1 000
Hinge opening angle110°, with a limit stop
Lockoutpadlockable from outside, still opens from inside when locked

That last line is an escape requirement and it is not optional on a manned shelter.

Materials, chosen for different reasons

Outer skin is stainless iron, because it only sees weather and carries no shielding duty. The knife is carbon steel, chosen for wear resistance at the contact line even though it is magnetic. The spring strip is beryllium copper with electroless nickel plating for corrosion. Three materials on one door because three different jobs.

Environmental, to GJB 6109-2007

ConditionRequirement
Operating temperature−45 °C to +55 °C
Storage temperature−55 °C to +70 °C
Thermal shock+70 °C to −55 °C cycling
MouldGJB 150.10A, growth grade 0 to 2
Salt sprayGJB 2093A, no coating or plating detachment
Damp heat95 % RH at 30 °C
RainGJB 6109-2007, 6 mm/min for 1 hour, no leakage
Vibration60 km motorway plus 20 km ordinary road and dirt, no damage or performance loss
Air tightness300 Pa overpressure, leakage under 1.0 m³/min
Thermal insulationgrade I, overall heat transfer coefficient under 1.5 W/(m²·°C) across a 55 °C differential

The rain, vibration, salt spray and air tightness requirements are what make this a shelter door rather than a laboratory door. A laboratory door has none of them and does not need them.

Relocatable panel rooms

Where the requirement is a laboratory that may move rather than a shelter that travels, the room is built as bolted modules on the same 3 m × 1 m grid as our fixed rooms, and the design decisions are:

Mobile shielded cabinets

For a single device, a trolley or bench sized shielded enclosure is usually the right answer, and it is a product we hold a utility model patent on: mobile shielded box, patent ZL 2023 2 0227113.X, granted 29 August 2023, publication CN 219612482 U. Inventors Hua Jun, Zhou Ting and Pan Xu.

The patent covers a shielded box on a mobile base with the door and the frame arranged so the seal stays true when the box is moved. That sounds like a small thing and it is the whole problem with mobile cabinets: a box that shields at 90 dB on a bench will walk itself out of alignment once it is on castors and moved a few hundred times.

What you lose by going mobile

Moving a room costs performance, and here is where:

None of these are fatal. All of them should appear in the quotation, and the ones that do not are the ones that will surprise you at the acceptance test.

Where we would steer you elsewhere. If you need 14 kHz at 90 dB or better, do not go mobile: build a welded room and stay in the building. If the shelter has to pass a specific national homologation for road transport, we will build to your chassis and your axle limits, but the homologation itself is your authority's process and we do not shortcut it. And if the move is one way only, once, ever, the money is better spent on a fixed room and a crane.

Frequently asked

How long does re-erection take?

For a panel room in the 3 × 3 × 2.5 m class with a small team and a clear floor, days rather than weeks, plus the shielding test. The test is the part that cannot be compressed.

Does the absorber travel with the room?

Yes, screw mounted so it comes down and goes back up. Ferrite tile does not survive rough handling well, so it ships in the original trays.

Can you ship a shelter as a container?

Panels and doors ship in standard containers, which is how the German project moved: two containers, heaviest pallet 2 100 kg. A complete shelter on a chassis is a different shipment and we will quote it against your route.

Where we have shipped

Market notes and project references, by country:

GermanyPolandUnited StatesCanadaUAE & GulfIndiaVietnamIndonesiaTurkeySouth Africa

Ask about mobile shielded rooms

Five fields, no registration. We reply to every enquiry within one working day.

Or email sales.cn@hmemc.com