Most shielding problems arrive as one device that has to be isolated, in a room that is not a lab, by someone who is not a shielding engineer. A cabinet solves that. It also solves it more cheaply than a room, which is why we build more cabinets than chambers.

When a cabinet beats a room

ConsiderationCabinetRoom
Equipment being testedone device, or a few small onesanything with a person inside
Floor spacea bench footprint, or a cornera room sized hole in your building
Costfraction of a roomproject scale
Moving it lateron a pallet, with the equipment insidea construction job
Access for a personnone, or a hand through a portyes
Antenna distancecentimetres, fixed geometrymetres, standards compliant
Environmental controlvent windows onlyHVAC, lighting, fire detection

The dividing line is usually the test standard. A cabinet cannot do a 3 m radiated emissions test, because the antenna cannot be 3 m away. It is excellent for pre-compliance, for isolating a single board during debug, for production screening, and for a device that must be tested where it lives.

The HM-SC series

Standard cabinets are built to order around the equipment envelope. What is fixed is the way they are made: bolted galvanised steel panels on a welded frame, the same double knife seal and beryllium copper strip as our room doors, and a penetration set specified with the order rather than added afterwards.

Cabinet classTypical clear sizeTypical attenuationUsual purpose
Bench top test box300 to 600 mm cube60 to 80 dB, 100 MHz to 6 GHzboard level debug, single module screening
Floor standing cabinet600 × 800 mm and up80 to 90 dB, 400 MHz to 6 GHzrack equipment, production test
Walk-in cabinet1.2 m and up, one personper project, often 90 dB to 18 GHzequipment that needs adjusting inside

Attenuation falls with size and with the number of penetrations. A small box with two connectors will beat a walk-in cabinet with thirty, every time, at the same panel specification. When someone quotes you one attenuation figure for the whole range of cabinet sizes, ask how many penetrations that figure was measured with.

A worked configuration: the HM-SC-TE107

This is a real order configuration, for a TE107 test system. The customer's problem was that the standard answer to housing a TE107 is a shielded room: expensive, needs floor space, and cannot be moved. The cabinet holds the same equipment on a trolley inside, at a fraction of the price.

The concept is worth noting on its own. A trolley runs into the cabinet, the equipment is assembled on it, and it is pushed inside. The cabinet then provides the 400 MHz to 6 GHz shielded environment around it. Because the equipment is on a trolley, it can be brought out for service without the shielding being disturbed.

Configuration

#ItemQuantity / spec
1Shielded cabinet body1
2Manual RF shielded door1, clear size 600 × 800 mm
3Honeycomb vent window3
4Power filter1, 32 A 220 V
5RJ45 filter3
6USB 2.0 filter4
7DB25 filter1
8DB9 filter4
9Water tube penetration1
10Fibre optic tube1
11SMA female connectors10
—Performance400 MHz to 6 GHz, 90 dB

Count the penetrations: three vents, one power, three network, four USB, one DB25, four DB9, ten SMA, plus water and fibre. That is twenty six holes in a box the size of a fridge, and 90 dB is still achievable because each one is filtered rather than just opened. The SMA bulkheads in particular are the ones people underestimate: ten coaxial feedthroughs is a lot of opportunity to lose 20 dB if the connectors are not shielded to the panel properly.

Water and fibre penetrations are in the list because real equipment needs them and pretending otherwise means the customer drills their own hole later, which is how cabinets get ruined.

What a cabinet will not do

Who we have supplied

Cabinet and component supply has gone to Intel, Ericsson, TDK, Qualcomm, Siemens, Broadcom, Foxconn, Flextronics, Huawei and Nokia, and we hold supplier certification with them. On the cabinet side that mostly means repeat orders and specific configurations rather than catalogue sales. The Indian semiconductor test cabinets for Broadcom are the clearest example, and that order came back a second time.

Where a cabinet is the wrong answer. If your test standard requires a specified antenna distance or a quiet zone, a cabinet cannot pass it and no amount of absorber inside will change that. If the device under test needs a person inside for more than a few minutes, buy a small room. And if the requirement includes 14 kHz magnetic, we will tell you so rather than sell you a box that fails the test.

Frequently asked

Can I get a cabinet with a window?

Yes, shielded glass at 80 to 300 mesh. It costs a little performance, mostly above 1 GHz.

How do I get cables in and out?

Filtered bulkheads, chosen at order. Send us the cable list, including the ones you think you will not need, because the empty port is cheap and the retrofit hole is not.

Does it need earthing?

Yes, a single point earth, same as a room. It is not optional on a shielded enclosure.