RF Shielded Cabinets and Test Boxes
Most shielding problems arrive as one device that has to be isolated, in a room that is not a lab, by someone who is not a shielding engineer. A cabinet solves that. It also solves it more cheaply than a room, which is why we build more cabinets than chambers.
When a cabinet beats a room
| Consideration | Cabinet | Room |
|---|---|---|
| Equipment being tested | one device, or a few small ones | anything with a person inside |
| Floor space | a bench footprint, or a corner | a room sized hole in your building |
| Cost | fraction of a room | project scale |
| Moving it later | on a pallet, with the equipment inside | a construction job |
| Access for a person | none, or a hand through a port | yes |
| Antenna distance | centimetres, fixed geometry | metres, standards compliant |
| Environmental control | vent windows only | HVAC, lighting, fire detection |
The dividing line is usually the test standard. A cabinet cannot do a 3 m radiated emissions test, because the antenna cannot be 3 m away. It is excellent for pre-compliance, for isolating a single board during debug, for production screening, and for a device that must be tested where it lives.
The HM-SC series
Standard cabinets are built to order around the equipment envelope. What is fixed is the way they are made: bolted galvanised steel panels on a welded frame, the same double knife seal and beryllium copper strip as our room doors, and a penetration set specified with the order rather than added afterwards.
| Cabinet class | Typical clear size | Typical attenuation | Usual purpose |
|---|---|---|---|
| Bench top test box | 300 to 600 mm cube | 60 to 80 dB, 100 MHz to 6 GHz | board level debug, single module screening |
| Floor standing cabinet | 600 × 800 mm and up | 80 to 90 dB, 400 MHz to 6 GHz | rack equipment, production test |
| Walk-in cabinet | 1.2 m and up, one person | per project, often 90 dB to 18 GHz | equipment that needs adjusting inside |
Attenuation falls with size and with the number of penetrations. A small box with two connectors will beat a walk-in cabinet with thirty, every time, at the same panel specification. When someone quotes you one attenuation figure for the whole range of cabinet sizes, ask how many penetrations that figure was measured with.
A worked configuration: the HM-SC-TE107
This is a real order configuration, for a TE107 test system. The customer's problem was that the standard answer to housing a TE107 is a shielded room: expensive, needs floor space, and cannot be moved. The cabinet holds the same equipment on a trolley inside, at a fraction of the price.
The concept is worth noting on its own. A trolley runs into the cabinet, the equipment is assembled on it, and it is pushed inside. The cabinet then provides the 400 MHz to 6 GHz shielded environment around it. Because the equipment is on a trolley, it can be brought out for service without the shielding being disturbed.
Configuration
| # | Item | Quantity / spec |
|---|---|---|
| 1 | Shielded cabinet body | 1 |
| 2 | Manual RF shielded door | 1, clear size 600 × 800 mm |
| 3 | Honeycomb vent window | 3 |
| 4 | Power filter | 1, 32 A 220 V |
| 5 | RJ45 filter | 3 |
| 6 | USB 2.0 filter | 4 |
| 7 | DB25 filter | 1 |
| 8 | DB9 filter | 4 |
| 9 | Water tube penetration | 1 |
| 10 | Fibre optic tube | 1 |
| 11 | SMA female connectors | 10 |
| — | Performance | 400 MHz to 6 GHz, 90 dB |
Count the penetrations: three vents, one power, three network, four USB, one DB25, four DB9, ten SMA, plus water and fibre. That is twenty six holes in a box the size of a fridge, and 90 dB is still achievable because each one is filtered rather than just opened. The SMA bulkheads in particular are the ones people underestimate: ten coaxial feedthroughs is a lot of opportunity to lose 20 dB if the connectors are not shielded to the panel properly.
Water and fibre penetrations are in the list because real equipment needs them and pretending otherwise means the customer drills their own hole later, which is how cabinets get ruined.
What a cabinet will not do
- Standard radiated emissions testing. No 3 m path, no standard antenna geometry.
- Hold a person comfortably. A walk-in cabinet is for adjustment, not for working a shift.
- Give you low frequency magnetic performance. Small steel enclosures are poor below about 100 kHz. If 14 kHz matters, this is the wrong product.
- Take a heavy trolley and stay flat. The base and the door alignment are tied together; tell us the trolley load up front.
Who we have supplied
Cabinet and component supply has gone to Intel, Ericsson, TDK, Qualcomm, Siemens, Broadcom, Foxconn, Flextronics, Huawei and Nokia, and we hold supplier certification with them. On the cabinet side that mostly means repeat orders and specific configurations rather than catalogue sales. The Indian semiconductor test cabinets for Broadcom are the clearest example, and that order came back a second time.
Frequently asked
Can I get a cabinet with a window?
Yes, shielded glass at 80 to 300 mesh. It costs a little performance, mostly above 1 GHz.
How do I get cables in and out?
Filtered bulkheads, chosen at order. Send us the cable list, including the ones you think you will not need, because the empty port is cheap and the retrofit hole is not.
Does it need earthing?
Yes, a single point earth, same as a room. It is not optional on a shielded enclosure.
Where we have shipped
Market notes and project references, by country:
Ask about shielded boxes
Five fields, no registration. We reply to every enquiry within one working day.