EMI Signal, Data and Control Line Filters for Shielded Enclosures
A shielded room with perfect walls and one unfiltered LAN cable is not a shielded room. The signal filter line is where most rooms quietly fail, because the power filter gets specified and the six data lines running to the equipment rack do not.
The filter families we build
| Family | Model prefix | Lines | Typical use |
|---|---|---|---|
| Telephone | HM-TEL | 2 to 16 pairs | analogue and digital phones, fax, intercom |
| LAN | HM-SF-LAN / HM-Signal-LAN | 8 core | Ethernet to 1 GbE |
| Serial | HM-Signal-RS485 | 2 wire pairs | RS485 / RS422 process control |
| USB | HM-USB2 / HM-USB-ALU | USB 2.0 | instrument data, USB storage |
| Video and audio | HM-Video / HM-Audio | 2 and 4 lines | monitoring, loudspeakers, CCTV |
| DVI | HM-SF-DVI / HM-DVI27 | DVI | display inside the room |
| Fire alarm | HM-SF-FireAlarm | 2, 4, 8, 10 and 4-wire variants | smoke and heat detection loops |
| Multiline control | HM-Signal-10 / 12 / 14 / 16 / 20 | 10 to 20 wires | process signals, interlocks |
| DB connectors | HM-DB25 / HM-DB9 | 25 and 9 pin | legacy instruments, PLC links |
| Fibre optic | waveguide tube and 6-way fibre feedthrough | 1 to 8 fibres | data where a copper filter cannot meet the spec |
Insertion loss: what to expect
Signal filters are specified by insertion loss in dB against frequency, not by a single flat number. Typical values for a well-matched data filter in a shielded room application:
| Frequency | Insertion loss |
|---|---|
| 150 kHz – 1 MHz | 40–60 dB |
| 1 – 30 MHz | 60–80 dB |
| 30 MHz – 1 GHz | 80–100 dB |
| 1 – 18 GHz | limited by the feedthrough, typically 80 dB or better |
We test and publish actual curves for the models where a customer needs the data for an acceptance package. If a supplier quotes "100 dB" for a data filter without a frequency axis, that figure is the feedthrough barrel, not the filter.
Choosing a filter, in the right order
- What is the signal doing? Bandwidth first. A filter that kills a 100 Mb/s Ethernet link is not a successful filter, it is a broken one. The insertion loss target follows from the signal, not the other way round.
- How many lines, and what connector? The filter body must fit the room's penetration panel, and the connector must match the customer's cable without an adapter inside the room.
- Is copper the right medium at all? Above roughly 1 GHz, and for any link that must be absolutely clean, fibre optic is the correct answer. A waveguide tube with a fibre feedthrough beats any copper filter because there is no conductor to leak.
- Then the attenuation target. It is the last requirement, not the first.
Reference programmes
- Russia, 2013–2016 — a wide family of filtered penetrations: 5 × 3 A, 2 × 50 A 400 Hz, 4 × 200 A 400 Hz, 4 × 300 A 400 Hz, DC 27 V 20 A, DC 36 V 15 A, 16-line telephone, 2/4/10/12-line signal
- Turkey — 2 × 30 A and 2 × 5 A power filters, 2013
- EMP applications — HM-EMP series, 30 A to 4 × 100 A, common mode and differential mode variants
- Shielded room programmes in Europe and Asia — LAN8, USB, RS485, fire alarm and video filters supplied as part of complete room packages
Frequently asked
Do I need a filter on a fibre optic line?
Not for EMI. The waveguide tube is a mechanical penetration for the fibre and a barrier to the field; there is no conductor, so there is nothing to filter. This is why fibre is cleaner than filtered copper.
Can you make a filter for a signal you have not made before?
Yes — we have designed one-off filters for customer requirements across a few hundred models. Send the signal, the voltage and current, the connector and the attenuation target, and we will quote.
Can a filter be retrofitted to an existing room?
Yes, if there is room on the penetration panel or the panel can be opened and replaced. The filter is usually the easiest thing to add to an existing room; the door seal is the hard one.
What about power filters?
Those are a separate and much larger line — 3 A to 2200 A, single and three phase, 400 Hz and DC. See EMI power line filters.
Where we have shipped
Market notes and project references, by country:
Ask about EMI signal filters