Home › Reverberation Chambers

Mode-Stirred Reverberation Chambers

A reverberation chamber is the opposite of an anechoic chamber: it wants reflections. The walls are metal, nothing absorbs, and a stirrer moves the field around until, statistically, every point in the working volume looks the same. That is why it can produce 200 V/m immunity fields in a room where an anechoic chamber would need an amplifier nobody can afford.

Why anyone wants one

PropertyReverberation chamberAnechoic chamber
Field at a given input powermuch higher — no absorber, energy stays in the roomlower, absorber takes energy out
Field uniformitystatistical, over the stirred volumepoint-by-point, in a defined quiet zone
Direction of arrivalall directions at once, randomly polarisedsingle direction, defined polarisation
Emissions measurementpossible, needs care with calibrationstandard method
Cost per V/mfar lower at high fieldcost rises steeply with field strength
Room treatmentbare metal wallsabsorber on all faces

The mechanics

ItemValue
Working principlemechanical stirrer creating a statistically uniform, isotropic field
Method standardIEC 61000-4-21
ShellRF shielded room, welded or modular, typically 80–100 dB
Stirrerpaddle type, motor driven, position monitoring for stir sequences
Sizingcustom — from component chambers to full vehicle chambers
Scopeshell, stirrer, filters, penetrations, instrumentation integration
Typical useradiated immunity at high field levels, shielding effectiveness of large equipment

Where it is the right answer

Where it is not

We have built one reverberation chamber, and we say so. Our experience with this product line is a single project — a chamber with a mechanical stirrer for a customer in Xi'an. We can design and build the shell, the stirrer and the penetrations, and we can integrate instrumentation supplied by others. We have not built a large automotive reverberation chamber, and we have not carried out the IEC 61000-4-21 statistical validation in-house. If your project is a full vehicle reverberation chamber with a certified field uniformity report, we are not the right supplier yet, and you should talk to a specialist in that product. If you need the shell, the stirrer and the penetrations to a specification written by your own RF engineer, we can do that competently and at a Chinese factory price.

What we contribute regardless

A reverberation chamber is mostly a shielded room with a big machine inside it, and the shielded room is our core product:

Shielded rooms EMC chambers Automatic and pneumatic doors Power line filters

Frequently asked

Can you supply only the stirrer?

Yes, if the customer has an existing shielded room with adequate performance and the opening can be made to suit. The stirrer must be dimensioned to the room, so we need the internal dimensions and the lowest usable frequency.

Does the room need absorber at all?

No — that is the point. A bare metal room is correct. Adding absorber reduces the field for a given input power, which defeats the purpose.

What is the lowest usable frequency?

It is set by the room volume and the stirrer, governed by the IEC 61000-4-21 mode-count criterion. As a rough indication, a small chamber of a few cubic metres is usable from a few hundred MHz upward; below that the mode density is too low for statistical uniformity.

Where we have shipped